How the house is built
The number one technical objection to light-gauge steel frame houses is the thermal bridge through the stud. Steel conducts heat far better than timber, and if the stud crosses the whole wall it becomes a loss channel across the full thickness of the insulation.
Our exterior wall has two independent structural zones: C140 with 140 mm of wool between the studs, then C89 with a further 60 mm of wool and a ventilated cavity behind the cladding. The studs of one zone never touch the studs of the other, so there is no continuous metal path from inside to outside.
It can be seen in the drawings below: the steel stud appears only as two bars, at the ends of the wool layer. The exterior finish is between 5 and 18 mm, depending on the material. The drawing uses an average value.
At a glance
- Exterior walls
- 0.18 W/m²K · 27.5-29 cm
- Roof
- 0.16 W/m²K · 263 mm
- Floor
- 0.21 W/m²K
- Glazing
- Ug 0.6-0.7 W/m²K
- Studs
- C140 and C89, 0.8 mm sheet steel
The build-ups
The thicknesses are those from the technical annex, drawn to proportion.
Exterior wallapprox. 275-290 mm
Schematic drawing. Thin layers are drawn exaggerated; the thicknesses written are the real ones.

Interior wall128 mm
Schematic drawing. Thin layers are drawn exaggerated; the thicknesses written are the real ones.
Bathroom wallapprox. 110 mm
Schematic drawing. Thin layers are drawn exaggerated; the thicknesses written are the real ones.
The waterproofing is continuous at the corners, at service penetrations and at the junction with the floor.
Roof263 mm + battens and roof covering
Schematic drawing. Thin layers are drawn exaggerated; the thicknesses written are the real ones.
Bituminous shingles are included in the base price. Metal roof tiles or a standing-seam metal roof can be chosen at +12 €/m².
Floor between storeysframe with 100 mm wool
Schematic drawing. Thin layers are drawn exaggerated; the thicknesses written are the real ones.
The two resilient layers structurally isolate the floor from the ceiling below. That is the difference between a lightweight house that sounds hollow and one that does not.

Ground floor slabas per the foundation design
Schematic drawing. Thin layers are drawn exaggerated; the thicknesses written are the real ones.
The thicknesses of the insulation and of the waterproofing are taken from the foundation design.
Thermal performance
The thermal transmittance, U, shows how much heat passes through the element. Lower is better. The right-hand column is the legal minimum.
| Element | Ours | C107 requirement |
|---|---|---|
| Exterior walls | 0.18 W/m²K | 0.35 W/m²K |
| Roof | 0.16 W/m²K | - |
| Floor | 0.21 W/m²K | - |
| Glazing | Ug 0.6 - 0.7 W/m²K | - |
- Studs
- C140 and C89, 0.8 mm sheet steel
- Coating
- AZ150 aluminium-zinc coating, minimum 150 g/m²
- Joinery
- Thermally broken aluminium, series 65, or uPVC, at the client's choice
- Heating
- Electric underfloor heating film, with smart thermostats
From the factory
Our own photographs from the production hall and from frames assembled in the factory yard.



The sound of a lightweight house
The floor between storeys has two resilient anti-vibration layers, above and below, which structurally isolate the floor from the ceiling underneath. That is the difference between a lightweight house that sounds hollow and one that does not.
The layers that make the difference
- Upper resilient acoustic layercontinuous at the interface with the truss6 mm
- Steel floor joists + wool100 mm, fitted without gaps100 mm
- Lower resilient acoustic layercontinuous at the interface with the ceiling6 mm